3 Unscrew the clamp bolt, and lift the
canister from its clamp on the body panel.

Refitting

4 Refitting is a reversal of removal, but ensure
that the hoses are correctly reconnected, as
noted before removal.

Solenoid valve

Removal

5 The solenoid valve is mounted on a bracket
next to the carbon canister, at the rear
left-hand corner of the engine compartment.
6 To remove the valve, first disconnect the
battery negative lead.
7 Unbolt the bracket from the body panel,
then disconnect the wiring plug (see
illustrations)
.

8 Disconnect the hoses from the valve, noting
their locations to ensure correct refitting, then
withdraw the valve.

Refitting

9 Refitting is a reversal of removal, ensuring
that the hoses are correctly reconnected, as
noted before removal.

4D•6 Exhaust and emission control systems

8.7a Unscrew the securing nut . . .

8.7b . . . and withdraw the solenoid bracket