Chapter 3: Starting Your PowerStation

PowerStation Connectors

PA PowerStation User Guide

3-10

Figure 3-8: Serial Printer Cable Diagram

Use Figure 3-8 as a reference when connecting a serial printer to the PA

PowerStation. Then complete the following steps:

1

From the Windows desktop, open the Startup directory within

Interact project:

C:\Machshop\Projects\Interact\*Project Name*\Startup\

Important Be sure to replace the pound sign with the appropriate

port number when completing the next step.

2

Within the Startup folder, create a new AUTOEXEC.BAT file with the

following line.

MODE COM#:baud,parity,databits,stopbits

For example, if you are communicating at 9600, NONE, 8, and 1, use
MODE COM1: 9600,N,8,1

3

Launch the MachineShop Toolbar.

Note When you download the project

containing AUTOEXEC.BAT

and MODE.COM from your development system to the

PowerStation

, MachineShop transfers the AUTOEXEC.BAT file you

created in step 2 and MODE.COM into the \STARTUP directory

specified by the INTERACT_STARTUP environment variable. This

environment variable resides in the PowerStation’s AUTOEXEC.BAT

file.

4

Download the project.

Note When MachineShop finishes the download, a prompt will

display asking whether you want to restart the computer.

When you restart, MODE.COM will configure the COM port to the
required baud rate.

5

Restart the PowerStation.