G-analyzer display switching – PhatNoise XXV-01D User Manual

Page 27

Advertising
background image

English

|

27

7

Exit display control mode

Turn the [VOL] knob to select "Return".
Press the [VOL] knob.

• When you selected the Display Type B display, select

an easy viewable font color.

• The "Indicator" item of Display type C/D can be set;

however, the actual display color does not change.

• This function can be set for each display type.
• When the SIRIUS tuner source in the 1-item 4-row

c

mode of Display type C/D, the same color is set for
both the upper and lower rows.

Display Type E

G-Analyzer display Switching

Alternates G-Analyzer display when the Display
type is set to "Display Type E". (G: gravity)

• Never watch the G-Analyzer Display screen when you

are driving.
Otherwise, a car accident may result.

• Before alternating G-Analyzer display, you are required

to setup <G-Counter Level set> (page 47) and <G-
Analyzer Calibration setup> (page 48).

1

Show the Multi-function display

Press the [NEXT] button repeatedly until
"Display" appears.
Refer to <Notes on Multi-function System> (page
9).

2

Enter display control mode

Turn the [VOL] knob to select "Display".
Press the [VOL] knob.

3

Select the display mode

Turn the [VOL] knob to select "Mode".
Press the [VOL] knob.
Select the "Display Type E" display.

4

Enter G-Analyzer display select mode
Turn the [VOL] knob to select "G-Menu".
Press the [VOL] knob.

5

Select the G-Analyzer display
Push the Control knob towards [

4] or

[

¢].

G-Analyzer display

G- Graphic display

G-Meter display

Point

Time

G-Counter display

• G-Graphic display:

Displays the condition of G in horizontal direction (e.g;
when turning the curve) by the graphic.

• G-Meter display (Graphic part):

Displays the maximum value of acceleration G, right
direction G, and left direction G by the numerical
value.

G-Meter display (Text part):

The maximum value of acceleration G, right direction
G, and left direction G is displayed by the numerical
value. The value of G is only the reference, so is
different from the actual value.

• G-Counter display:

Adds the point of the acceleration level. The point is
determined after a lapse of 1 hr drive or at power off
(ACC Off ), and then it will be displayed by the graph.
Furthermore, the G-Counter displays the average
of the past data by the line. (The scale of graph is
determined along with the largest point among the
past 10 data.)

• The value of G-Meter display and G-Counter display

can be reset by <G-Analyzer Reset> (page 47).

6

Exit display control mode
Turn the [VOL] knob to select "Return".
Press the [VOL] knob.

Advertising