Installation of lightning protectors, Installation of an earth rod, Outside – Panasonic KX-T206E User Manual

Page 18

Advertising
background image

18

Installation of an Earth Rod

Notice
If you install an extension outside of the main building, the following precautions are recom-
mended:
(1) Install the extension wire underground.
(2) Use a conduit to protect the wire.

Note
• The lightning protector for an extension is different from that for CO.

(1) Installation location of the earth rod ...... Near the protector
(2) Check obstructions ................................ None
(3) Composition of the earth rod ................. Metal
(4) Depth of the earth rod ............................ More than 50 cm
(5) Size of the earth wire ............................. Thickness is greater

than 1.6 mm

Notes
• The above figures are recommendations only.
• The length of earth rod and the required depth depend on the

composition of the soil.

Installation of Lightning Protectors

Outside

Earth

SLT

PT

EXTN

EXTN

EXTN

EXTN

CO

CO

CO

Protectors

(Another Building)

(Main Building)

Main

Distribution

Frame

Main

Unit

Lightning

Protector

TEL

TEL

Lightning

Protector

Main

Unit

(Underground)

Earth Rod

Earth Wire

CO

Advertising