Specifications

General Descriptions

1. Capacity .................................... CO line

2

Extension

6

2. Control Method ......................... Stored Program CPU: 8 bits CPU

Control ROM: 64 KB, Control RAM: 8 KB

3. Switching Method ..................... Space Division CMOS Crosspoint Switch

4. Power Supplies ......................... Primary

AC 110–240 V, 50/60 Hz

Secondary

Circuit Volt: +5V, +15 V, +30 V

Power Failure

CO 2 assigned to extension 22

5. Dialling

Outward

Dial Pulse

10 PPS

Tone Dial

Internal

Dial Pulse

10 PPS, 20 PPS

Tone Dial

Mode Conversion

DP-DTMF, DTMF-DP

6. Connector .................................. CO

4-pin connector

Extension

4-pin connector

Doorphone

4-pin connector

7. EXT Connection ....................... Cable

1 pair wire (single line telephone)
2 pair wire (proprietary telephone)

8. Intercom paths ........................... 2 (including the doorphone path)

Characteristics

1. Station Loop Limit .................... Proprietary telephone

40 ohms

Single line telephone

600 ohms including set

Doorphone

20 ohms

2. Minimum Leak Resistance ....... 15000 ohms

3. Maximum Number of Station

Instruments per line .................. 1 (proprietary telephone) or 3 (single line telephone)

4. Ring Voltage .............................. 90 Vrms at 25 Hz depends on Ringing Load

5. Primary Power .......................... AC 110–240 V, 50/60 Hz, 0.5 A maximum

6. Central Office Loop Limit ........ 1600 ohms maximum

7. Environmental Requirements ... 0–40˚C, 10%–90% (Humidity)