Maintenance – Porter-Cable C7501M User Manual

Page 14

Advertising
background image

14 - ENG

N020206

MAINTENANCE

CUSTOMER RESPONSIBILITIES

Before

each

use

Daily

or

after

each

use

Every

8

hours

Every

40

hours

Every

100

hours

Every

160

hours

Yearly

Check Safety Valve

Drain Tank

Oil Leaks

Check Pump Oil

Change Pump Oil

Unusual Noise and/or

Vibration

Air Filter

(1)

Drive Belt-Condition

Motor Pulley/Flywheel

alignment

Air compressor pump

intake and exhaust

valves

Inspect air lines and

fittings for leaks

Head Bolts - Check the torques of the head bolts after the first five hours of operation.
1- more frequent in dusty or humid conditions

Risk of unsafe operation. Unit cycles automatically when

power is on. When performing maintenance, you may be exposed to voltage

sources, compressed air, or moving parts. Personal injuries can occur. Before

performing any maintenance or repair, disconnect power source from the

compressor and bleed off all air pressure.
To ensure efficient operation and longer life of the air compressor outfit, a routine

maintenance schedule should be prepared and followed. The following routine

maintenance schedule is geared to an outfit in a normal working environment

operating on a daily basis. If necessary, the schedule should be modified to suit the

conditions under which your compressor is used. The modifications will depend

upon the hours of operation and the working environment. Compressor outfits in

an extremely dirty and/or hostile environment will require a greater frequency of all

maintenance checks.
NOTE: See Operation section for the location of controls.

TO CHECk SAFETY VALVE

Risk of bursting. If the safety valve does not work properly,

over-pressurization may occur, causing air tank rupture or an explosion.

Risk from flying objects. Always wear certified safety equip-

ment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields.
1. Before starting compressor, pull the ring on the safety valve to make sure

that the safety valve operates freely. If the valve is stuck or does not operate

smoothly, it must be replaced with the same type of valve.

Advertising