N020206

PROBLEM

CAUSE

CORRECTION

Compressor is

not supplying

enough air

to operate

accessories

Prolonged excessive

use of air.

Decrease amount of air usage.

Compressor is not large

enough for air requirement.

Check the accessory air

requirement. If it is higher than

the SCFM or pressure supplied

by your air compressor, you

need a larger compressor.

Hole in hose.

Check and replace if required.

Check valve restricted.

Remove and clean, or replace.

Air leaks.

Tighten fittings.

Restricted air intake filter.

Clean or replace air intake filter.

Do not operate the air compressor

with the filter removed. Refer

to the

Air Filter paragraph in

the Maintenance section.

Loose belt.

Loosen wingnut and then

tighten wingnut until it contacts

the washer, plus one turn.

Restricted

air intake

Dirty air filter.

Clean or replace. See

Air

Filter paragraph in the

Maintenance section.

Motor will

not run

Motor overload protection

switch has tripped.

Refer to

Motor Overload Protection

under Operation. If motor overload

protection trips frequently, contact

a Trained Service Technician

Tank pressure exceeds

pressure switch "cut-

in" pressure.

Motor will start automatically when

tank pressure drops below "cut-

in" pressure of pressure switch.

Check valve stuck open.

Remove and clean, or replace.

Loose electrical

connections.

Check wiring connection

inside pressure switch and

terminal box area.

Possible defective motor

or starting capacitor.

Have checked by a Trained

Service Technician.

Paint spray on internal

motor parts.

Have checked by a Trained Service

Technician. Do not operate the

compressor in the paint spray area.

See flammable vapor warning.

Pressure release valve on

pressure switch has not

unloaded head pressure.

Bleed the line by pushing the

lever on the pressure switch to

the "Off" position; if the valve

does not open, replace switch.

Advertising