Power supply requirements, Table 1-2. power supply requirements – Hamilton Sundstrand Company Gas Fuel Metering Valve HFG2.0 User Manual

Page 22

Advertising
background image

16 HFG2.0

USER

GUIDE

Note: A battery system is recommended for highest reliability.

Note: If a 120 VDC power supply is used rather than a battery,

ensure an output capacitance of at least 12,000 µF, which
can both sink and source electric current. See Power
Supply Requirements (Table 1-2).

Note: Use a separate conduit for the power wiring. This prevents

noise pickup and transmission from ancillary equipment,
which could cause instability in the actuator.

Power Supply Requirements

Table 1-2 below lists the power supply requirements for the HFG2.0.

PARAMETER

VALUE

Voltage

Nominal
Range


120 VDC
80 – 160 VDC

Max. Ripple

4 VAC RMS or 12 VAC p-p

Current

Maximum

Continuous , Typical

Transient,

Typical


20 Amps
<1 Amp
+20 A <60 ms
+10 A <600 ms
-5 A <100 ms

*Output Capacitance

12,000 µF (typical)

Table 1-2. Power Supply Requirements

*The output capacitance applies for non-battery power systems and assumes full-stroke step
changes in actuator position at rated load. This value is typical. The actual value required is
dependent on the user’s specific DC power system design, including:

Power sources used in the DC power system (their output impedance, transient response,
rating, diode decoupling [if any], topology, etc.)

All electrical loads and components connected to each respective power bus branch

Switching relationships of these electrical loads and components to each other (for example,
does a large motor and actuator turn off at about the same time, etc.)

Bus branch conductor length and arrangement (flat bus bars, round cables, twisted, etc.)

Advertising