Planet Technology DVR-1670 User Manual

Page 83

Advertising
background image

If you want to view the log based on default option, just press ENTER key. DVR will list all
matched information. Also you can select options to search (By Type, By Date, By
Type&Date).

By Type
To view log information of the assigned type.
Type is divided into “Major type” and “Minor type”. Major type includes operation, alarm,
exception and all.
For operation major type, there are many minor types, including Power On, Shut Down,
Abnormal Shut, Panel Login, Panel Logout, Panel Config, Panel File Play, Panel Time Play,
Local Start Record, Local Stop Record, Panel PTZ, Panel Preview, Panel Set Time, Local
Upgrade, Net Login, Net Logout, Net Start Record, Net Stop Record, Net Start Transparent
Channel, Net Stop Transparent Channel, Net Get Parameter, Net Config, Net get Status, Net
Alert On, Net Alert Off, Net Reboot, BiComStart (Start Voice Talk), BiComStop (Stop Voice
Talk), Net Upgrade, Net File Play, Net Time Play, Net PTZ.
For alarm major type, the minor type includes External Alarm In, External Alarm Out,
Motion Detect Start, Motion Detect Stop, View Tamper Start, View Tamper Stop.

For exception major type, the minor type includes Video Signal Loss, Illegal Access, Hard

Disk Error, Hard Disk Full, IP Conflict, DCD Lost.



For example

The steps of viewing alarm log.

Step 1

For “Query” item, select “By Type” to active “Major Type” and “Minor Type” items.

Step 2 For “Major Type” option, select “Alarm” option. For “Minor Type” option, select one
of following options All, External Alarm In, External Alarm Out, Motion Detect Start,
Motion Detect Stop, View Tamper Start, View Tamper Stop .

Step 3 Move “Active Frame” to “Search Log” button, press ENTER key to start searching.

Page 83

Advertising