Appendix E Troubleshooting

Failure Possible

reasons

After plugging in power, turning on the power switch,
“POWER” light in front Panel does not turn on, and fan
does not work.

1) Power cable is broken.
2) Power supply is broken.

After plugging in power, turning on the power switch,
“POWER” light in front panel turn to green while fan does
not work.

1) Front panel cable is broken.
2) Fan is broken.

After plugging in power, turning on switch, “POWER”
light turn to green, the indicator lights in the panel turn on
at the same time, but fan does not work.

The ATX plug in main board is
not well plugged in.

DVR continuously reboots after start up, and makes a
sound like “di” every 10 seconds.

1) Upgrade the wrong firmware
2) Compression board has

problems.

3) Main board has problems.

There are no images in the monitor connected with VOUT
after DVR is started.

1) The cable connected with the

monitor is broken.

2) Real board of DVR has

problems.

3) Main board of DVR has

problems.

Cannot find the hard disk in reboot process.

1) Hard disk cable is broken.
2) The power cable of hard disk

is not connected.

3) Hard disk is broken.

No reponse in HyperTerminal interface.

1) Baud rate is not matched.
2) RS-232 cable is broken.
3) Serial port of PC is broken.
4) RS-232 port of DVR is

broken.

DVR can not control PTZ through RS-485 port.

1) RS-485 cable is not

connected correctly or
broken.

2) PTZ parameters error.
3) RS-485 port of DVR is

broken.

Client software can not view DVR live image.

1) Network is error.
2) Connect wrong DVR (wrong

IP, port number, username or
password, ect).