2. Turn the regulator knob counterclockwise to set the outlet pressure to zero.
3. Remove the air tool or accessory.
4. Pull ring on safety valve allowing air to bleed from the tank until tank pressure

is approximately 20 psi. Release safety valve ring.

5. Drain water from air tank by opening drain valve on bottom of tank.

Risk of Bursting. Water will condense in the air tank. If not

drained, water will corrode and weaken the air tank causing a risk of air tank

rupture.

Risk of Property Damage. Drain water from air tank may contain oil

and rust which can cause stains.
6. After the water has been drained, close the drain valve. The air compressor

can now be stored.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be

removed, cleaned, the reinstalled.

SERVICE AND ADjUSTMENTS

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE
PERFORMED BY TRAINED SERVICE TECHNICIAN.

Risk of Unsafe Operation. Unit cycles automatically when

power is on. When servicing, you may be exposed to voltage sources, com-

pressed air, or moving parts. Before servicing unit unplug or disconnect

electrical supply to the air compressor, bleed tank of pressure, and allow the

air compressor to cool.

TO REPLACE OR CLEAN CHECk VALVE

1. Release all air pressure from air tank.

See To Drain Tank in the Maintenance

section.

2. Unplug unit.

3. Remove the hose by removing the hose

Check Valve

Hose Clamp

clamp.

NOTE: The hose clamp is not reus-

able. You must purchase a new hose clamp,

see

Replacement Parts in the Service sec-

tion or purchase a standard hose clamp at a

local hardware store.

4. Unscrew the check valve (turn counterclock-

wise) using a socket wrench.

5. Make sure the valve disc moves freely inside

the check valve and the spring holds the disc in the upper, closed position.

The check valve may be cleaned with a solvent, such as paint and varnish

remover.

6. Apply sealant to the check valve threads. Reinstall the check valve

(turn clockwise).

7. Replace hose and new hose clamp.