Storage – Porter-Cable CF6131 User Manual

Page 14

Advertising
background image

14 - ENG

TO REPLACE REGULATOR

1. Release all air pressure from air tank.

Safety

Valve

Regulator

Manifold

Gauges

Quick Connect

See

To Drain Tank in the Maintenance

section.

2. Unplug unit.
3. Using an adjustable wrench remove

the gauges, quick connect, and safe-

ty valve from the regulator manifold.

4. Remove the hose by removing the

hose clamp.

NOTE: The hose clamp

is not reusable. You must purchase a

new hose clamp, see

Replacement

Parts in the Service section or purchase a standard hose clamp at a local

hardware store.

5. Remove pump mounting screws securing pump (one on each side).

Regulator

Manifold

Hose

Clamp

Pump Mounting Screw

6. Carefully slide pump from

Regulator

Manifold

Pump shown

moved out of

the way

brackets and out of the way.

7. Using an adjustable wrench

remove the regulator manifold.

8. Apply pipe sealant to new regula-

tor manifold and assemble, tight-

en with wrench.

9. Reapply pipe sealant to gauges,

quick connect, and safety valve.

10. Reassemble all components in

reverse order of removal. Make sure to orient gauges to read correctly and

use wrenches to tighten all components.

STORAGE

Before you store the air compressor, make sure you do the following:
1. Review the Maintenance section on the preceding pages and perform

scheduled maintenance as necessary.

2. Drain water from air tank. See

To Drain Tank under Maintenance.

Water will condense in the air tank. If not drained, water will

corrode and weaken the air tank causing a risk of air tank rupture.
3. Protect the electrical cord and air hose from damage (such as being stepped

on or run over). Wind them loosely around the compressor handle.

4. Store the air compressor in a clean and dry location.

Advertising