Specifications, Troubleshooting, Continued – Procom EN250RYLB-O User Manual

Page 15

Advertising
background image

1 5

SPECIFICATIONS

Btu 20,000/25,000 20,000/ 25,000

Gas

Type

LP Gas Natural Gas

Ignition Automatic Automatic

Manifold Pressure 8"W.C. 3"W.C.

Inlet Gas Pressure

(In. of water)*

Maximum 14" 10.5"

Minimum 11" 5"

Dimensions, Inches (H×W×D)
Stove 38 3/16”Ч26 3/8”Ч14 1/8”
Carton 40 1/8”Ч29 5/16”Ч15 5/16”
Weight, lbs

Stove 78

Shipping 94

voltage 120 120

watt

27

27

*For purposes of input adjustment

EL250RYLB-O

EN250RYLB-O

Delayed ignition burner

1. Manifold pressure is too low
2. Burner orifice clogged

1. Contact local gas company
2. Clean burner (see Cleaning and
Maintenance,
page 12)

Burner backfiring during combustion

1. Damaged burner
2. Gas regulator defective

1. Clean burner orifice (see Cleaning
and Maintenance
, page 12)
2. Replace gas regulator

Slight smoke or odor during initial
operation

1. Residues from manufacturing
processes
2. Not enough air
3. Gas regulator defective

1. Problem will stop after a few hours
of operation
2. Check burner for dirt and debris.
If found, clean burner (see Cleaning
and Maintenance
, page 12)
3. Replace gas regulator

Dark residue on logs or inside of
fireplace

1. Improper log placement
2. Air holes at burner inlet blocked
3. Burner flame holes blocked

1. Properly locate logs (see installing

logs, page 21)

2. Clean out air holes at burner inlet.

Periodically repeat as needed.

3. Remove blockage or replace burner

Heater produces a clicking/ticking
noise just after burner is lit or shut off

1. Metal expanding while heating
or contracting while cooling

1. This is common with most heaters. If
noise is excessive, contact qualified
service person

TROUBLESHOOTING

Continued