Panasonic AJ-HPX2000 User Manual

Page 179

Advertising
background image

179

Menu : Menu Description Tables

Me
n

u

The ____ in the Adjustable Range column indicates the
preset mode.

BATTERY SETTING1

Items/

Data Saved

Adjustable

Range

Remarks

PROPAC14

¢

Enable selection under BATTERY
SELECT.
¢:Enable selection.
: Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR
END voltage.
AUTO: Set voltage automatically.
MANUAL:Set voltage manually.

11.0

:

13.8

:

15.0

When MANUAL is selected in the above
menu, set the NEAR END voltage in 0.1
V steps.

– C U F –

TRIMPAC14

¢

Enable selection under BATTERY
SELECT.
¢:Enable selection.
: Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR
END voltage.
AUTO: Set voltage automatically.
MANUAL:Set voltage manually.

11.0

:

13.6

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1
V steps.

– C U F –

HYTRON50

¢

Enable selection under BATTERY
SELECT.
¢:Enable selection.
: Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR
END voltage.
AUTO: Set voltage automatically.
MANUAL:Set voltage manually.

11.0

:

13.5

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1
V steps.

– C U F –

HYTRON140

¢

Enable selection under BATTERY
SELECT.
¢:Enable selection.
: Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR
END voltage.
AUTO: Set voltage automatically.
MANUAL:Set voltage manually.

11.0

:

13.5

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1
V steps.

– C U F –

DIONIC90

¢

Enable selection under BATTERY
SELECT.
¢:Enable selection.
: Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR
END voltage.
AUTO: Set voltage automatically.
MANUAL:Set voltage manually.

11.0

:

13.6

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1
V steps.

– C U F –

Items/

Data Saved

Adjustable

Range

Remarks

DIONIC160

¢

Enable selection under BATTERY
SELECT.
¢:Enable selection.
: Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR
END voltage.
AUTO: Set voltage automatically.
MANUAL:Set voltage manually.

11.0

:

13.2

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1
V steps.

– C U F –

NP-L7

¢

Enable selection under BATTERY
SELECT.
¢:Enable selection.
: Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR
END voltage.
AUTO: Set voltage automatically.
MANUAL:Set voltage manually.

11.0

:

13.2

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1
V steps.

– C U F –

ENDURA7

¢

Enable selection under BATTERY
SELECT.
¢:Enable selection.
: Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR
END voltage.
AUTO: Set voltage automatically.
MANUAL:Set voltage manually.

11.0

:

13.2

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1
V steps.

– C U F –

ENDURA10

¢

Enable selection under BATTERY
SELECT.
¢:Enable selection.
: Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR
END voltage.
AUTO: Set voltage automatically.
MANUAL:Set voltage manually.

11.0

:

13.2

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1
V steps.

– C U F –

ENDURA-D

¢

Enable selection under BATTERY
SELECT.
¢:Enable selection.
: Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR
END voltage.
AUTO: Set voltage automatically.
MANUAL:Set voltage manually.

11.0

:

13.2

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1
V steps.

– C U F –

AJ-HPX2000P(VQT1D27-1)E.book 179 ページ 2007年7月30日 月曜日 午後1時31分