203987 Rev A RCP2-1000 RM Remote Controller Operations Manual

Pin # Function Description

1

Closed on Power Supply Fault Form C relay NC

2

Opened on Power Supply Fault Form C relay NO

20

Power Supply Fault Common

3

1. Standalone mode. Closed on Auxiliary Fault
2. 1:1 Redundancy Mode. Closed on Automatic switchover mode. Form C relay NC

21

1. Standalone Mode. Opened on Auxiliary Fault
2. 1:1 Redundancy Mode. Closed on Manual switchover mode. Form C relay NO

22

Auxiliary Fault\Auto-Manual Common

4

Closed on Mute. Form C Relay NC

5

Opened on Mute. Form C Relay NO

23

Mute Status Common

6

Closed on BUC Fault. Form C Relay NC

24

Opened on BUC Fault. Form C Relay NO

25

BUC Fault Common

7

Closed on High Temperature Fault. Form C Relay NC

8

Opened on High Temperature Fault. Form C Relay NO

26

High Temperature Fault Common

9

1. Standalone mode. Closed on Regulator Low Voltage Fault

2. 1:1 Redundancy Mode. Closed on HPA Standby. Form C relay NC

27

1. Standalone Mode. Opened on Regulator Low Voltage Fault.

2. 1:1 Redundancy Mode. Closed on HPA Online Mode. Form C relay NO

28

Regulator Low Voltage Fault\Standby-Online Common

10

Closed on DC Current Low Fault. Form C Relay NC

11

Opened on DC Current Low Fault. Form C Relay NO

29

DC Current Low Fault Common

12

Closed on Low Output RF Fault. Form C Relay NC

30

Opened on Low Output RF Fault Form C Relay NO

31

Low Output RF Fault Common

17

Mute/Unmute toggle input. 50mS Closure to ground to activate

35

SSPA Standby input. 50mS Closure to ground to activate

36

RCP Local/Remote toggle. 50mS Closure to ground to activate

37

Fault clear. 50mS Closure to ground to activate

Table 2-3: Parallel I/O Pin Out

19 Ground

34, 33,
32, 18,
16, 15,

14, 13

Reserved. Make No Connection.