Paradise RCP2-1000 User Manual

Page 25

Advertising
background image

RCP2-1000 RM Remote Controller Operations Manual

203987 Rev A

25

3.2.4.2 Fault Latch

Determines the alarm reporting condition. A latched alarm will remain indicated on the
front panel until the operator clears the alarm by pressing the “Enter” button. Unlatched
alarms will allow the summary alarm indicator to stop displaying the alarm condition if
the circumstance creating the alarm has been cleared or corrected.

3.2.4.3 Control Mode

Selects between Local and Remote mode.

3.2.4.4 Panel ID

Displays the serial number and firmware revision of the RCP unit.

3.2.5 Options Sub-Menu

This menu makes available functions to backup or restore settings, set a password or
the brightness of the LCD, and test the LED lamps on the front panel.

3.2.5.1 Backup User Settings

Allows the user to backup all settings to nonvolatile memory.

3.2.5.2 Restore

Restores saved settings, either those from a previous backup (User), or to those as
shipped from the factory (Factory).

3.2.5.3 Lamp Test

This selection activates all LED indicators on the front panel, including the Fault Indica-
tors, Amplifier Selection, Signal Path Mimic Display, Local/Remote Key and Auto/
Manual Key. Press “Enter” to exit the Lamp Test.

3.2.5.4 Password

Allows the user to set (Enable), change or clear (Disable) a password that prohibits
others from changing controller settings. A number from 1-255 can be selected. Use
front panel navigation keys to set the number. Up/Down arrows change the number by
factors of 10. Left/Right arrows change the number in increments of 1.

3.2.5.5 Reset

Cycles power to the RCP2-1000.