Port

740 CAMERA/DATA1-4 PORT

SWITCHER=MASTER(5 of 5)

PORT MODE SPEED
CAMERA TERMINAL-K1 9600bps
DATA1 TERMINAL-K2 9600bps
DATA2 TERMINAL-K3 9600bps
DATA3 MASTER-SLAVE 38400bps
DATA4 PS-DATA 9600bps
HDR HDR 9600bps

SERIAL PC 38400bps

Master unit setting for Master-Slave connection

Slave unit setting for Master-Slave connection

SWITCHER:

Select a unit (SLAVE1 to 4 and MASTER*) to

configure the parameters.

* In normal connection, only MASTER is displayed.

The factory default setting is same as the illustration.

PORT:

This stands for the type of a port.

CAMERA:

RS-485 Camera port

DATA 1/2/3/4:

DATA 1/2/3/4 ports

HDR:

DATA HDR port

SERIAL:

SERIAL port

MODE:

This stands for the operation mode of a port.

CAMERA:

Select this if a camera is connected.

TERMINAL-K1/K2/K3/K4:

Select this if a terminal-mode

system controller is connected.

PS·DATA:

Select this if a PS·DATA system controller is

connected.

MASTER-SLAVE:

The port used for the master-slave

connection is fixed to this parameter.

HDR:

The HDR port is fixed to this parameter.

PC:

WJ-SX150A Administrator Console configuration

and firmware update becomes available with a PC
connection.

VCR:

Select this if a time-lapse VCR (Panasonic model)

is connected.

– – –:

This port is unusable.

The following are MODE parameters assigned to
each port.

740 CAMERA/DATA1-4 PORT

SWITCHER=SLAVE1(1 of 5)

PORT MODE SPEED
CAMERA CAMERA 19200bps
DATA1 CAMERA 19200bps
DATA2 CAMERA 19200bps
DATA3 CAMERA 19200bps
DATA4 MASTER-SLAVE 38400bps
HDR HDR 9600bps

SERIAL -- 38400bps

The factory default setting is same as the illustration.

SPEED:

This stands for the communication speed of a port.

38400 bps*:

Select this to set the speed to 38400 bps.

19200 bps:

Select this to set the speed to 19200 bps.

9600 bps:

Select this to set the speed to 9600 bps.

4800 bps:

Select this to set the speed to 4800 bps.

* This parameter is available only for SERIAL.

The factory default setting is same as the illustration.

Notes:

• If the DATA 4 is set to PS·DATA, SPEED of PS·DATA will

be changed in conjunction with that of HDR.

• When you change MODE, the default communication

speed is automatically set. The SERIAL port is set to the
default speed when CONTROL is changed in 600
RECORDER. (Refer to p. 71.)

The default communication speeds are shown in the dia-
gram.

MODE

Factory default setting

CAMERA

19200 bps

TERMINAL

9600 bps

PS·DATA

9600 bps

HDR

9600 bps

PC

38400 bps

VCR (VTR)

9600 bps

CAMERA

DATA 1

DATA 2

DATA 3

DATA 4

HDR

SERIAL

Master

Normal connection

CAMERA

TERMINAL-K1/K2/
K3/K4
CAMERA
TERMINAL-K1/K2/
K3/K4
CAMERA

TERMINAL-K1/K2/
K3/K4
CAMERA

TERMINAL-K1/K2/
K3/K4
PS

·

DATA

HDR

PC

Master-slave connection

TERMINAL-K1/K2/
K3/K4
CAMERA

TERMINAL-K1/K2/
K3/K4
CAMERA

TERMINAL-K1/K2/
K3/K4
CAMERA

MASTER-SLAVE

TERMINAL-K1/K2/
K3/K4
PS

·

DATA

HDR

PC

Slave 1
to 4

CAMERA

CAMERA

CAMERA

CAMERA

MASTER-
SLAVE

HDR

– – –

VCR

VCR

VCR

Advertising