Mux camera title mux, How to display, How to edit – Panasonic WJ-SX 150A User Manual

Page 75: Mux camera title

Advertising
background image

78

• NORMAL

EXT.:

Select this to gen-lock the unit during the normal

operation.

002,004 to 255 (field):

Select one of these normal

recording rates if the asynchronous unit is connect-
ed to the unit.

The factory default setting is EXT.

• DYNAMIC REC

PRI.:

Select this to give recording priority to the camera

channel with the alarm input.

ONLY:

Select this to record the images from the alarm-

associated camera channel.

GROUP:

Select this to give recording priority to a group

of up to 4 camera channels associated to the alarm
input.

OFF:

Select this to deactivate the alarm priority mode.

The factory default setting is OFF.

• DUMMY BLACK

ON:

Select this to display the black picture for a camera

channel that is not connected to the camera.

OFF:

Select this to skip the camera channels that are

not connected to the camera in the sequence/spot
mode.

The factory default setting is ON.

• CAM SW LOSS

ON:

Select this to make “CAMSW LOSS R

” light up on

the associated monitor when loss of the camera
switching pulse is detected.

OFF:

Select this not to make “CAMSW LOSS R

appear on the associated monitor when loss of the
camera switching pulse is detected.

The factory default setting is ON.

Note:

If EXT. is selected for 910 ALARM/920 NORMAL,

the playback images cannot be displayed on the
monitors which are not connected to the EXT IN
connector. Confirm the images on those which are
connected to the recorder.

MUX CAMERA TITLE

How to Display

To display this menu on the monitor, move the cursor to
1000 MUX CAMERA TITLE in SETUP MENU by moving the
joystick to D or C. Then, press the CAM (SET) button. The
submenu appears on the monitor.

How to edit

The factory default settings are same as the illustration.
The editing procedure is the same as 500 CAMERA TITLE.
(Refer to p. 71.)

Notes:

• Up to 8 alphanumeric characters are available for

each Multiplexer board camera title.

• When moving the joystick to D at the last text box

of CAM 8 TITLE, the cursor will move to the first text
box of CAM 9 TITLE.

• When moving the joystick to C at the first text box

of CAM 9 TITLE, the cursor will move to the last text
box of CAM 8 TITLE.

• If five units are connected in the system, you can

configure no parameters for MASTER.

MUX

1000 MUX CAMERA TITLE

SWITCHER=SLAVE1(1 of 3)

CAM LCN TITLE CAM LCN TITLE
1 1 C01 9 09 C09
2 2 C02 10 10 C10
3 3 C03 11 11 C11
4 4 C04 12 12 C12
5 5 C05 13 13 C13
6 6 C06 14 14 C14
7 7 C07 15 15 C15
8 8 C08 16 16 C16

LCN:LOGICAL CAMERA NUMBER

Advertising