Parameters (slave 1 to 4), Recorder, How to display – Panasonic WJ-SX 150A User Manual

Page 94: Parameters

Advertising
background image

97

Parameters (Slave 1 to 4)

The following are different from normal connection and
Master.

• RS485, DATA1 to 3 is fixed to Camera.
• DATA 4 is used for master-slave connection. Protocol is

fixed to Master-Slave and Baud Rate is fixed to 38400.

• When VCR is selected for 600 RECORDER in SETUP

MENU (refer to p. 71), the Protocol of SERIAL is fixed to
VCR. This parameter is activated when using a
Pananonic time-lapse VCR.

• When Protocol of SERIAL is displayed as “– – –“, Baud

Rate is set to the baud rate for firmware update.
Refer to p. 58 for details.

(Save Exit) button

Saves the configuration and closes the Data Port window.

(Cancel Exit) button

Cancels the configuration and closes the Data Port window.

Recorder

This window configures the recorder setting parameters:
whether the multiplexer board is installed in the unit, what is
the type of the recorder, what is the recorder unit address,
and whether the gen-lock is activated.

How to Display

To display this window, click on the

(Recorder Mode)

button in the main window (p. 80).

Parameters

• Recorder Control

Click on the desired radio button to determine the recorder
type.

OFF:

Select this when no recorder is connected to the

unit.

HD500:

Select this when a WJ-HD500 Series recorder

is connected to the unit.

HD100:

Select this when a WJ-HD100 Series recorder

is connected to the unit.

HD200:

Select this when a WJ-HD200 Series recorder

is connected to the unit.

VCR/VTR:

Select this when a time-lapse VCR is con-

nected to the unit.

Note:

VCR/VTR is selectable only in the Slave tabs.

The factory default setting is HD500.

• Unit Address

This parameter is configurable only when HD100, HD200 or
HD500 is selected in the Recorder window. When OFF is
selected there, this parameter is displayed in gray and not
configurable. 1 to 99 is selectable. The factory default set-
ting is 1.

Note:

If you connect a time-lapse VCR to the Master unit,

do the recorder setting in SETUP MENU. (Refer to
RECORDER in p. 71.) If you connect a time-lapse VCR
to Slave units, recorder setting is available in WJ-
SX150A Administrator Console.

MUX

MUX

Advertising