Setting up the Rack

Install the recorder into an EIA standard compliant rack.

Note:

Installation in a rack requires four M5 x 12 screws.

1

Remove the 5 rubber feet from the underside of the
recorder.
Use a screwdriver to remove the screws holding the rubber
feet.

2

Attach the handle for rack mounting bracket to the rack
mounting brackets.
Use the four handle fixing screws for rack mounting bracket
and washers to secure them.

3

Attach the rack mounting bracket to both sides of the
recorder.
Secure them using the six rack mounting bracket fixing
screws.

4

Install the recorder in the rack.
Secure using the rack mounting screws.

Rack Mounting

EIA standard compliant
product

(locally procured)

: an EIA-standard 19"rack, depth

550 mm or more

Remove rubber feet

Handle for rack mounting bracket

Rack mounting bracket

Handle fixing screws for
rack mounting bracket

Washer

Washer

Rack mounting brackets (provided)

Handle for rack
mounting bracket

Handle for rack
mounting bracket

Rack mounting bracket fixing screws (provided)

Important:

Ensure that the temperature inside the rack does not exceed
45 ºC {113 ºF}.

During installation, we recommend installing a fan to keep the
temperature in the rack below 30 ºC {86 ºF}.

When installing the recorder in the rack, leave a space of
1 unit (44 mm {1.73"}) above and below each unit.

Leave space between racks and ensure proper ventilation
around the racks.

Rack mounting screws (M5 x 12, locally procured)

chap3.fm 23 ページ 2008年4月8日 火曜日 午後5時22分