About Connectors

38

*The error output timing is set under [Basic] on the settings menu (refer to the Setup Instructions (PDF file)).

Note:

During L active (Low active), the logic is enabled when the signal's voltage level is Low.

During H active (High active), the logic is enabled when the signal's voltage level is High.

Alarm/Control connector and Alarm Connector Timing and Polarity

Connectors

Active Time

Remarks

Alarm input

100 ms or more

L active

Alarm output

The time set on the setup menu

L active

Network error output

Until the network error is cleared, or until the [ERR] button on
the operation window (browser) is clicked.

L active

Alarm reset input

100 ms or more

L active

Emergency recording input

100 ms or more

L active

Available disk space warning output

From the time of the error occurrence until the time of the
error output duration

*

L active

HDD error output

From the time of the error occurrence until the time of the
error output duration

*

L active

Camera error output

From the time of the error occurrence until the time of the
error output duration or the camera is reset

*

L active

Error output

From the time of the error occurrence until the time of the
error output duration

*

L active

Time adjustment input/output

Input: 100 ms or more
Output: 1 s

Input/Output:
L active

Alarm suspension input

100 ms or more

L active, judged level

External recording mode switching

100 ms or more

L active

Outage detection input

5 s or more

L active

Power outage recovery completion
output

10 s or more

H active