Rack mounting positions, Setting up the rack – Panasonic WJ-ND400 User Manual

Page 24

Advertising
background image

Setting up the Rack

24

When connecting multiple extension units (WJ-HDE400) to the recorder, place the recorder in the center of the rack.

Connect the recorder and the extension unit with the connection cable (1 m {39.4 "}) included with the extension unit.

Note:

Install the recorder in the center of the rack, if using a rack. If you install the recorder at the top or bottom of the rack, the cable may not be
long enough.

When installing the recorder in the rack, leave a space of 1 unit (44 mm {1.73 "}) above and below each unit.

Secure the connection cables to the extension unit using the cable clamp provided.
If the connection is poor, the system may become unstable and unable to record images.

Keep the cables as short as possible. Looped cables or large distances between pieces of equipment may cause malfunctions. Also, do not
bend the cables more than 90º, wind the cables in a coil (10 cm {3.94 "} in diameter).

Refer to the Setup Instructions (PDF file) to check the unit numbers of connected extension units.

Rack mounting positions

Extension unit
(unit number 4)

Connection cable
(provided with extension unit)

Requires 1 Unit

Extension unit
(unit number 5)

Extension unit
(unit number 1)

Extension unit
(unit number 3)

Requires 1 Unit

Requires 1 Unit

Requires 1 Unit

At least 10 cm

Cable coil example

Round cable coil

Requires 1 Unit

Extension unit
(unit number 2)

Network Disk
Recorder