Hdd error recovery (during raid operation), Using the front panel for operations – Panasonic WJ-ND400 User Manual

Page 52

Advertising
background image

Using the Front Panel for Operations

52

When errors occur during RAID5 or RAID6 operation, the HDD errors in the following table are displayed.

When one HDD has errors ([1down]) in RAID5 mode, the data on the remaining HDDs can be read and recovery is possible.

When two HDDs have errors ([2down]) in RAID6 mode, the data on the remaining HDDs can be read and recovery is possible.

When any errors occur on an HDD, replace the effected HDD as soon as possible.

For details refer to the operating instructions for the extension unit.

*Contact your dealer for information on replacing HDDs.

HDD Error Recovery (During RAID Operation)

Important:

RAID5 mode
Data cannot be recovered when two or more HDDs have errors ([2 down]) or when an HDD has errors during recovery.

RAID6 mode
Data cannot be recovered when three or more HDDs have errors ([3 down]) or when an HDD has errors during recovery.

Data source

During HDD error (malfunction)

During recovery

Recorder/
Extension
unit

LCD

RAID 1 DOWN:
[1down]

RAID 2 DOWN:
[2down]

RAID 3 DOWN (only while in RAID6
mode):
[3down]

Note:

Only extension units are shown.

HDD access indicator

Lights red:
Errors have occurred on HDD
(Data can be recovered by replacing the
HDD)

When in RAID5 mode, the first HDD has
errors

When using RAID6, the first two HDDs
have errors

Blinks red:
Errors have occurred on HDD
(Data cannot be recovered even if HDD is
replaced)

When in RAID5 mode, the second HDD
has errors

When in RAID6 mode, the third HDD
has errors

Alternating orange/red
HDD being recovered in RAID5/RAID6

Recorder

[Error Log]
Refer to the Operating
Instructions (PDF file) for
more information.

RAID 1 DOWN
Recorder: MAIN RAIDm 1 DOWN
Extension unit: EXTu RAIDm 1 DOWN

RAID 2 DOWN
Recorder: MAIN RAIDm 2 DOWN
Extension unit: EXTu RAIDm 2 DOWN

RAID 3 DOWN
Recorder: MAIN RAID6 3 DOWN
Extension unit: EXTu RAID6 3 DOWN

m: Operational mode
u: Unit number

RAID recovery failure

Recorder
MAIN RAIDm RECOVERY FAILURE

Extension unit
EXTu RAIDm RECOVERY FAILURE

m: Operational mode
u: Unit number

ND400_Basic.book 52 ページ 2008年4月8日 火曜日 午後3時59分

Advertising