Niles Audio MRZ-6 User Manual

Page 17

Advertising
background image

IR Connections for a System with two or more Preamp/Receivers and MRZ-6’s

This system is very similar to the single zone receiver/single MRZ-6 system. See Figure 20.

• A 12VDC wall adapter is connected to the switched outlet of each of the Preamp/Receivers to provide sync

(or status) to their MRZ-6.

• The CONTROL OUT of each MRZ-6 is connected to the input of the AC-3 which is used to power up those

shared sources which have latching power.

Note: The MRZ-6 is diode isolated internally, blocking diodes

are not required.

• DATA OUT of the Slave is connected to the DATA IN of the Master. The Slave will pass IR data to the Master

for control of the shared sources via the Master’s common flasher outputs. See Figure 15.

• The UART connection enables All On and All Off control of all the rooms in the system. See page 20 of the

MRZ-6 manual.

• Both ZONE DIP switches should be set to the DOWN (or multi-zone) position. In this position, IR com-

mands passed through the other MRZ-6’s will not be routed to the Dedicated flasher. This enables identical
Preamp/Receiver commands to be used for both the home theater and the multi-room sound systems inde-
pendently, while the commands used to control the shared sources are output via the Master MRZ-6’s
Common flasher outputs.

• When using RP-9 keypads with or without IntelliPads or IR sensors, all automation codes are taught to both

MRZ-6’s.

For more information concerning IntelliPad®/MRZ-6 programming, see page 126of MRZ-6 manual.

15

0 1 0 : 0 0

O O : 0 0

O O : 0 0

93.9 FM

STEREO

93.9 FM

STEREO

COMMON

ZONE

ALL ON

CTRL
OUT

POWER
16VAC

FLASHER

LEVEL

ADJUST

1

G
N
D

D
A
T
A

+
1
2
V

2

G
N
D

D
A
T
A

+
1
2
V

3

G
N
D

D
A
T
A

+
1
2
V

4

G
N
D

D
A
T
A

+
1
2
V

5

G
N
D

D
A
T
A

+
1
2
V

6

G
N
D

D
A
T
A

+
1
2
V

IN

OUT

FLASHERS

IR DATA

DEDI-
CATED

12V

SYNC

IR SENSOR/KEYPAD INPUTS

V E

UART
+ -

MAIN
INPUT

ROOM 1
OUTPUT

ROOM 2
OUTPUT

ROOM 3
OUTPUT

ROOM 4
OUTPUT

ROOM 5
OUTPUT

ROOM 6
OUTPUT

L

R

L

R

L

R

L

R

CASCADE
OUTPUT

L

R

L

R

L

R

L

R

Niles Audio Corporation, Inc.
Miami, Florida USA

MODEL MRZ-6

This device complies with part 15 of the FCC Rules. Operation is sub-
ject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.

COMMON

ZONE

ALL ON

CTRL
OUT

POWER
16VAC

FLASHER

LEVEL

ADJUST

1

G
N
D

D
A
T
A

+
1
2
V

2

G
N
D

D
A
T
A

+
1
2
V

3

G
N
D

D
A
T
A

+
1
2
V

4

G
N
D

D
A
T
A

+
1
2
V

5

G
N
D

D
A
T
A

+
1
2
V

6

G
N
D

D
A
T
A

+
1
2
V

IN

OUT

FLASHERS

IR DATA

DEDI-
CATED

12V

SYNC

IR SENSOR/KEYPAD INPUTS

V E

UART
+ -

MAIN
INPUT

ROOM 1
OUTPUT

ROOM 2
OUTPUT

ROOM 3
OUTPUT

ROOM 4
OUTPUT

ROOM 5
OUTPUT

ROOM 6
OUTPUT

L

R

L

R

L

R

L

R

CASCADE
OUTPUT

L

R

L

R

L

R

L

R

Niles Audio Corporation, Inc.
Miami, Florida USA

MODEL MRZ-6

This device complies with part 15 of the FCC Rules. Operation is sub-
ject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.

IN

OUT

+ —

+ —

Figure 20 IR Connections for a System with two or more Preamp/Receivers and MRZ-6’s

From tape or pre-out

To switched outlet

To CONTROL IN

To switched outlet

From tape or pre-out

Slave MRZ-6

Master MRZ-6

Niles AC-3