No display:

1. Check DC power connections and DC polarity with voltmeter.

2. Check fuse.

No flow reading indicated:

1. Check connection to flow transducer.

2. Remove transducer from fuel line, blow through transducer, a whistling noise will indicate the

turbine is rotating.

Low flow reading indicated:

1. Check that the gauze filter is clean. If the filter is not installed fine strands may clog up the

turbine.

2. Check calibration is correct.

High or erratic reading:

Check fuel connections are well made. Air in fuel lines will cause erratic or high readings.

Appendix B - Troubleshooting Chart