00 trp tot, Alr 8 14, Alr 0 12 0ff – Navman FUEL 2100 User Manual

Page 5

Advertising
background image

5

FUEL 2100 Installation and Operation Manual

NAVMAN

Setting the low fuel alarm

Use the

key to select the alarm function. The LCD

will indicate

ALr

for two seconds and will then display

the present alarm value. If no alarm value has been
entered the LCD will indicate

0FF

.

TOTAL

FLOW

^

V

ALr

0

12 0FF

Press and hold both keys for three seconds and the
displayed value will begin to flash.

Press and hold for 3 seconds

8

12

Use the

and

keys to select the desired alarm

value. Press and hold both keys for one second to
save this new value to memory and to exit this function.
The display will indicate

ALr

and then the new value.

ALr

8

14

#

The arrow pointing at the alarm bell will be activated.

Alarm activation

If the fuel remaining value drops below the fuel alarm
value, the alarm will sound and the alarm arrow will
flash.

12

#

Press any key to mute the alarm. The alarm arrow
will continue to flash as long as the alarm condition
remains.

Resetting the TRIP LOG or
the TOTAL LOG

To reset a log, press the

key until the display

indicates the name of the log to be reset.

Press and hold both keys for three seconds. Display
will show

trP

or

tOt

for 2 seconds before resetting

to zero.

Press and hold for 3 seconds

0

00

trP tOt

The trip log value may be reset without changing
the total log value.

If the total log is reset to zero, then the trip log
will automatically reset to zero.

Note :

If the total log exceeds 999 then both it

and the trip log will be reset to zero.



Advertising