Cascading, Limitations, Cable connections – Network Technologies UNIMUXUSBVXHD User Manual

Page 42: Master slave slave, Hdusbvext-xx-mm

Advertising
background image

NTI UNIMUX SINGLE-USER HIGH DENSITY VGA USB KVM SWITCH

37

CASCADING


The UNIMUX USB Matrix switch can be expanded to access up to 1024 CPUs by cascading multiple units together. As many
switches as there are CPU ports may be connected to a UNIMUX USB Matrix switch. (See Figure 41) All downstream switches
are referred to as "slaves" in a cascaded system. The only additional hardware required to cascade switches is a set of device
and monitor cables for each “SLAVE UNIT” (see MATERIALS on page 2). All CPUs and switches can then be controlled by
users using OSD commands with Command Mode.

Limitations

The front panel keypad is only used to operate standalone switches. To control a cascaded network of switches, only the OSD
commands within Command Mode will be recognized.

Users connected to accessible ports on downstream slaves (i.e. ports not connected to the master) will not be able to control
switches or CPUs connected upstream. Only control over CPUs and slaves downstream from a user's connection point will be
enabled. (See Figure 41)

Slaves in a cascaded system must be either all single-user switches or all multi-user switches, but not a combination of both.

Cable Connections

The same cable used to connect a CPU to the UNIMUX is used to connect two UNIMUX-USBV-xHD switches together-
HDUSBVEXT-xx-MM. No other cables will be necessary. To connect a slave to a master

1. Connect the USB-A-male end of the HDUSBVEXT-xx-MM to the USER port on the slave.

2. Connect the 15HD male at the same end of the HDUSBVEXT-xx-MM cable to the MONITOR port on the slave.

3. Connect the yellow 15HD male end of the HDUSBVEXT-xx-MM to the CPU 1 port on the master.

Repeat this procedure for each USER and MONITOR port on each slave that is desired to be controlled through the master.

The same procedure can be used to connect multi-user switches (UNIMUX-nXm-UHDU) as slaves (see Figure 42).

Figure 41- Cascading with only single-user units

250V,2A

12 4

11 3

10 2

9 1

CPU

CPU

16 8

15 7

14 6

13 5

CPU

CPU

NETWORK TECHNOLOGIES INCORPORATED 1275 Danner Drive, Aurora Ohio 44202 330-562-7070 www.networktechinc.com

MONITOR

RS232

HDUSBVEXT-xx-MM

250V,2A

12 4

11 3

10 2

9 1

CPU

CPU

16 8

15 7

14 6

13 5

CPU

CPU

NETWORK TECHNOLOGIES INCORPORATED 1275 Danner Drive, Aurora Ohio 44202 330-562-7070 www.networktechinc.com

MONITOR

RS232

250V,2A

12 4

11 3

10 2

9 1

CPU

CPU

16 8

15 7

14 6

13 5

CPU

CPU

NETWORK TECHNOLOGIES INCORPORATED 1275 Danner Drive, Aurora Ohio 44202 330-562-7070 www.networktechinc.com

MONITOR

RS232

HDUSBVEXT-xx-MM

Rear View of UNIMUX-USBV-16HDU

Rear View of
UNIMUX-USBV-16HDU

Rear View of
UNIMUX-USBV-16HDU

Master

Slave

Slave

Advertising