Electrical, Clean air furnace - wiring diagram – Lifebreath 4TONDHW(T) User Manual

Page 29

Advertising
background image

29

JUMPER

OPTIONAL PUMP TIMER

1 LOAD

2 LINE

3 NEUT.

4

5

R

W

C

Y

G

24VAC THERMOSTAT CONNECTIONS

GND

TRANSFORMER

24V

NC

NO

NO

C

C

NC

120V

LINE

NEUTRAL

NO

NC

com

HIGH

Speed Select

red

white

blue or brown

black

yellow

Door Interlock
Switch

3
0

2
0

FAN MOTOR

FAN
CAPACITOR

PUMP

black

yellow

blue

MED-HIGH

MED

CAF-01

0101

2

1

Continuous/Automatic
Ventilation Switch

WARNING
1 AMP
MAX
FUSE

* NOTE: Units with
an (Optional) Pump
Timer do not get an
(Optional) Temperature
Sensor

* OPTIONAL
TEMPERATURE
SENSOR

The Clean Air Furnace operates at 120V, singles
phase and draws anywhere from 2-8.7 amps,
depending on fan speed.

The low voltage thermostat (not provided)
connects to the R & W terminals for heating and
the R & Y & C terminals when calling for cooling.

Caution should be used if installing a setback
thermostat to control the system. If the
thermostat is set back too far, and, for example,
is set to call for a lot of heat when you get out of
bed, at which time showering and general water
use is at its peak, then the hot water heater may
not keep up.

Clean Air Furnace - Wiring Diagram

To change fan speed, move

bottom wires on the speed

select terminal block to the high,

med-hi or med location.

Note:
Unit is shipped on high speed.

R - W

= Heat

R - G

= Fan Only (optional dehumidistat)

G - R - Y - C

= A/C

Electrical