Part E - SYSTEM START UP

E.1

Fill Water Heater with water

E.2

Set Water Heater at designed temperature

E.3

Fill Heating Loop with water

E.4

Purge Circulation Pump

E.5

Start Air Handler

E.6

Check Circulation Pump Operation

E.7

Check Circulation Fan Operation

E.8

Label Water Heater

Part F - SYSTEM COMMISSIONING

F.1

Supply Water Temp.

________

o

F

(measured)

F.2

Air Handler Output

at F.1 Condition

________ Btu/h

F.3

Air Handler Operating CFM

________ CFM

(from specs)

F.4

Return Air Temperature

________

o

F

(measured)

F.5

Required Air
Temperature Difference

________

o

F

(F.2

÷

(F.3 x 1.08))

HRV BALANCING

Exhaust Air Flow

_______________________________

Fresh Air Intake Air Flow _______________________________

Back Draft Damper installed in Stale Air to Outside Duct

F.6

Required Supply Air Temperature ________

o

F

(F.4 + F.5)

F.7

Returned Water Temperature

________

o

F

(measured)

F.8

Water Temperature Difference

________

o

F

(min. 20

o

F)

(F.1 - F.7)

F.9

Actual Supply Air Temperature

________

o

F

(measured)

F.10 Anti-Scald Valve (if present)

Outlet Temperature

(measured)

________

o

F

Design Information: (Information for this section can be found on the " Worksheet for Integrated Combo System Design" part B)

Total Heat Loss __________ Btu/h

Air Handler: output __________ Btu/h

Eff. Water Heater output __________ Btu/h

Air Handler ESP: _________ ins. W.C.

Air Flow rate: __________ CFM

Fan speed __________

Supply Water temp.: ______

o

F Return Water temp.: ______

o

F Supply Air temp.: _______

o

F Return Air temp.: ______

o

F