NEC PlasmaSync 4210W User Manual

Page 49

Advertising
background image

42

04. VOLUME Gain Data
Function

The external control equipment changes the VOLUME gain data of the PlasmaSync 4210W.

Transmission Data

DFH 80H

60H

7FH

03H

DATA00

DATA01

DATA02

CKS

DATA00: USER SOUND Gain Flag

05H

DATA01: VOLUME Gain Flag

01H

DATA02: VOLUME Gain

00H: Step 0

0AH: Step 10 (Default)

2AH: Step 42

ACK

7FH

60H

80H

7FH

02H

DATA00

DATA01

CKS

DATA00: USER SOUND Gain Flag

05H

DATA01: VOLUME Gain Flag

01H

05. SCREEN MODE Select
Function

The external control equipment switches the screen mode of the PlasmaSync 4210W.

Transmission Data

DFH 80H

60H

51H

01H

01H DATA00

CKS

DATA00

02H : STADIUM
03H : ZOOM
04H : NORMAL
05H : FULL

ACK

7FH

60H

80H

51H

01H

DATA00

CKS

DATA00

02H : STADIUM
03H : ZOOM
04H : NORMAL
05H : FULL

06. AUDIO Mute On
Function

The external control equipment switches on AUDIO Mute of the PlasmaSync 4210W.

Transmission Data

9FH

80H

60H

3EH

00H

CKS

ACK

3FH

60H

80H

3EH

00H

CKS

07. AUDIO Mute Off
Function

The external control equipment switches off AUDIO Mute of the PlasmaSync 4210W.

Transmission Data

9FH

80H

60H

3FH

00H

CKS

ACK

3FH

60H

80H

3FH

00H

CKS