NEC PlasmaSync 4210W User Manual

Page 51

Advertising
background image

44

10. TINT Gain Data
Function

The external control equipment changes the TINT gain data of the PlasmaSync 4210W.

Transmission Data

DFH 80H

60H

7FH

03H

DATA00 DATA01

DATA02 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: TINT Gain Flag

05H

DATA02: TINT Gain

EAH: -22

FFH: -01
00H: 0
01H: +01

16H: +22

ACK

7FH

60H

80H

7FH

02H

DATA00

DATA01

CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: TINT Gain Flag

05H

11. SHARPNESS Gain Data
Function

The external control equipment changes the SHARPNESS gain data of the PlasmaSync 4210W.

Transmission Data

DFH 80H

60H

7FH

03H

DATA00 DATA01

DATA02 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: SHARPNESS Gain Flag

06H

DATA02: SHARPNESS Gain

F0H: -16

FFH: -01
00H: 0
01H: +01

10H:+16

ACK

7FH

60H

80H

7FH

02H

DATA00

DATA01

CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: SHARPNESS Gain Flag

06H

12. CONTRAST Gain Data
Function

The external control equipment changes the CONTRAST gain data of the PlasmaSync 4210W.

Transmission Data

DFH 80H

60H

7FH

03H

DATA00 DATA01

DATA02 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: CONTRAST Gain Flag

07H

DATA02: CONTRAST Gain

00H : 0

34H: +52

ACK

7FH

60H

80H

7FH

02H

DATA00

DATA01

CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: CONTRAST Gain Flag

07H

Advertising