BASIC OPERATION

Static Convergence Adjustment

Adjust for the red and blue CRTs to place their pattern on top of the

green test pattern (center only).

NOTE: The static convergence adjustment should be performed for
R and B CRT. Carry out the adjustment after displaying an active
image for 20 minutes or more.

Proceed as follows:

1 Press the OPERATE button.

• The “OPERATE” menu is displayed.

2 Use the CURSOR

or

button to highlight the “6/STATIC”

line and then press ENTER to display the STATIC adjustment

screen. You can also select the STATIC adjustment screen

directly by pressing the INPUT “6” button , or by pressing the

STATIC button on the remote control.

• The CROSS-HAIR test pattern will be automatically displayed.

3 Press the R or B button to display the pattern to be aligned with

the Green pattern (as used a reference color).

• You can turn on or off each CRT beam (R and B) separately.

4 Hold down the CTL button then select the CRT you wish to

adjust with the R and B buttons.

5 Align the center of the Red or the Blue pattern with the center of

the Green pattern using the CURSOR buttons.

• The CURSOR

or

button moves the pattern right or left.

The CURSOR

or

button moves the pattern up or down.

6 Repeat steps 3 to 5 for the other CRTs if necessary.

7 To end this adjustment, press the END button.

• Whenever the END button is pressed, the screen changes in this

order:

“OPERATE” menu

Source screen

– O P E R A T E –

1 / P I C T U R E

2 / P O S I T I O N

3 / S O U N D

4 / I N P U T S E L E C T

5 / S O U R C E I N F O

6 / S T A T I C

7 / C L O S E D C A P T I O N

8 / T I M E R

+ 1 0 %

– 1 0 %

V

H

C O N V E R G E N C E

– S T A T I C –

C R T – R –

Red or Blue

Green

Advertising
This manual is related to the following products: