NEC NEAX2000 ND-91649 User Manual

Page 52

Advertising
background image

CHAPTER 5

ND-91649(E)

Page 44

SPECIFICATIONS

Table 5-1 System Capacity (Single MP System) (Cont’d)

Note 4: Message Waiting Lamp is not available when the 4LLC is mounted in slot 08 to 10.

Note 5: From FP 3300, maximum 256 PS can be accommodated to the system in addition to the maximum 512

LT ports.

Ex: 400 Dterms

+

100 CO Lines=500 LT Ports

150

PSs

Note 6: Total number of CS and IP-BS should be 128 or less.

Note 7: Maximum voice channels per IP trunk card depends on the payload size as follows (payload size can be

assigned by system data programming):

CCIS (p-p/p-mp) and Peer-to-Peer

Payload Size

G.729a

G.711

G.723.1

10 ms

4 Channel

4 Channel

------

20 ms

8 Channel

8 Channel

------

30 ms

16 Channel

16 Channel

16 Channel

40 ms

16 Channel

16 Channel

------

VoIP (H.323)

Payload Size

G.729a

G.711

G.723.1

20 ms

6 Channel

5 Channel

---

30 ms

8 Channel

7 Channel

8 Channel

40 ms

12 Channel

10 Channel

---

Note 8: It is possible to connect 4 applications at the same time.