Assigning i/o signal numbers – Nortech Systems Adept RS-232/TERM User Manual

Page 99

Advertising
background image

Configuring a Single sDIO

Adept SmartController User’s Guide, Rev. E

99

5. Type N at the following prompt.

Attached controller 0. Change this value?

Then, press ENTER to continue.

6. Type Y at the following prompt.

Digital input block: 16 Change this value?

Then, press ENTER to continue.

7. Enter a new value for the input block at the following prompt.

Enter new value:

Then, press ENTER to continue.

8. Type Y at the following prompt.

Digital output block: 16 Change this value?

Then, press ENTER to continue.

9. Enter a new value for the output block number at the following prompt.

Enter new value:

Then, press ENTER to continue.

10. Type Y at the final prompt.

Do you want to save these changes?

Then, press ENTER to continue.

After selecting block numbers, you must assign groups of signal numbers to each block.

NOTE: You must select a unique block number for the Inputs and Outputs
of each sDIO in your system. Repeat the procedure above for each sDIO.

Assigning I/O Signal Numbers

The I/O signal number ranges are valid for the sDIO:

• Inputs 1033 to 1512

• Outputs 0033 to 0512

You will need to perform the follow steps to assign I/O signals to specific blocks, if you
choose a block other than 16.

1. Load and Execute the CONFIG_C.V2 utility.

2. Select option 2.

2 - V+ System Configuration Data

Then, press ENTER to continue.