100 Mb Fiber Transceiver Characteristics

Fiber Length

2km*

15km**

40km**

80km**

TX Power Min/Max

-19dBm/-14dBm

-15dBm/-7dBm

-5dBm/0dBm

-5dBm/0dBm

RX Sensitivity Max

-32dBm

-29dBm

-34dBm

-34dBm

Wavelength Min/Max

1310nm

1310dm

1310dm

1550nm

* Multimode Fiber Optic Cable
** Singlemode Fiber Optic Cable

Gigabit Fiber Transceiver Characteristics

Fiber Length

550m* with
50/125 µm

300m* with
62.5/125 µm

10km**

40km**

70km**

TX Power
Min/Max

-9.5dBm/-4dBm

-9.5dBm/-4dBm

-5dBm/0dBm

-4dBm/1dBm

-3dBm/2dBm

RX Sensitivity
Max

-17dBm

-17dBm

-20dBm

-21dBm

-23dBm

Wavelength

850nm

850nm

1310nm

1550nm

1550nm

Assumed
Fiber Loss

-3.5 dB/km

-3.75 dB/km

-0.5 dB/km

-0.25 dB/km

-0.20 dB/km

Laser Type

VCSEL

VCSEL

FP

DFB

DFB

*SX Fiber Optic Cable
** LX Fiber Optic Cable




Regulatory Approvals:

Safety:
UL 1604 (US and Canada) Hazardous Locations, Class I, Div 2, Groups A, B, C, D, T4A

EMI:

EN61000-6-4, EN55011 – Class A
FCC Title 47, Part 15, Subpart B - Class A

EMS: EN61000-6-2

EN61000-4-2 (ESD)

EN61000-4-3 (RS)

EN61000-4-4 (EFT)

EN61000-4-5 (Surge)

EN61000-4-6 (Conducted Disturbances)


Conducted Low Frequency: IEC60533

Shock:

IEEE 1613 (250 mm)

Vibration:

IEEE 1613 (V.S.3 20 mm/s)

IEC60068-2-6 (Test Fc)

Cold:

IEC60068-2-1

Dry Heat:

IEC60068-2-2

Damp Heat:

IEC60068-2-30 (Test Db)