Apx-11, Appendix 2 – Runco DTV-992 User Manual

Page 62

Advertising
background image

APX-11

Appendix 2

TOUCH-UP

When TOUCH-UP is selected, only the static convergence of
the currently selected source will be carried out automatical-
ly. Follow the steps below to select:

Highlight TOUCH-UP by pushing up or down keys of the
control disc;

Press the <ENTER> button to start up the static conver-
gence.

If the process is successfully completed, the projector will
return to image display of the current source.

ALIGN ON CURRENT SOURCE

When ALIGN is selected, the automatic convergence on the

current memory bank will be carried out automatically, start-
ing from the existing settings.

By projecting alternately red and blue line, 25 convergence
areas are aligned to the green pattern.

Follow the steps below to select:

Highlight ALIGN below ON CURRENT SOURCE by
pushing up or down keys of the control disc;

Press the <ENTER> button to start up the automatic
convergence of the entire screen.

If the process is successfully completed, the projector will
return to image display of the current source.

Use this option when the convergence is close to proper
alignment.

ALIGN FROM MIDPOSITION ON CURRENT SOURCE

When ALIGN FROM MIDPOSITION is selected, the auto-
matic convergence on the current source will be carried out
automatically, but starting from the mid-position settings.

By projecting alternately red and blue lines, 25 convergence
areas are aligned to the green pattern.

Follow the steps below to select:

Highlight ALIGN FROM MIDPOSITION by pushing up or
down keys of the control disc;

Press the <ENTER> button to start up the automatic
convergence of the entire screen.

If the process is successfully completed, the projector will
return to image display of the current source.

Use this option when the convergence is far from proper
alignment.

ADJUSTMENT MODE

Select a path from below:

EYE-Q

GUIDED
RANDOM ACCESS
INSTALLATION
SERVICE

Source 1

Select with
then <ENTER>.
<EXIT> to return

or

EYE-Q

TOUCH UP

AUTOCONVERGENCE
QUICK AUTOPICTURE

FULL AUTOPICTURE

EYE-Q SETUP

EYE-Q DIAGNOSTICS

Select with
then <ENTER>.
<EXIT> to return

or

EYE-Q

TOUCH UP

AUTOCONVERGENCE

QUICK AUTOPICTURE

FULL AUTOPICTURE

EYE-Q SETUP

EYE-Q DIAGNOSTICS

Select with
then <ENTER>.
<EXIT> to return

or

AUTOCONVERGENCE

ON CURRENT SOURCE:

ALIGN

ALIGN FROM MIDPOSITION

ON ALL SOURCES: (XX)

TOUCH-UP

ALIGN

ALIGN FROM MIDPOSITION

Select with
then <ENTER>.
<EXIT> to return

or

STATUS:
ready

EYE-Q

TOUCH UP

AUTOCONVERGENCE

QUICK AUTOPICTURE

FULL AUTOPICTURE

EYE-Q SETUP

EYE-Q DIAGNOSTICS

Select with
then <ENTER>.
<EXIT> to return

or

AUTOCONVERGENCE

ON CURRENT SOURCE:

ALIGN

ALIGN FROM MIDPOSITION

ON ALL SOURCES: (XX)

TOUCH-UP

ALIGN

ALIGN FROM MIDPOSITION

Select with
then <ENTER>.
<EXIT> to return

or

STATUS:
ready

Advertising