LDK 5481 + LDK 4700 User’s Guide | Base unit

3-5

Do not twist the cable when connecting it to equipment.

Insert connectors straight and fully into their corresponding sockets.

In fiber optic cable systems always put the dust caps on cable and panel connectors
immediately after disconnecting a cable. Keep the dust caps clean.

Installation information

Ventilation

Cold air is taken in from the right side and expelled on the left side (see drawing).

Do not block the air inlet or outlet;

Clean the air inlet grill at least once a year.

Rack mounting instructions

Note that rack mounting is not mandatory for the unit. When the unit is mounted in a 19” rack
ensure that the following instructions are observed:

The unit is supported at the rear;

If installed in a closed or multi-rack assembly, the operating ambient temperature of the
rack environment may be greater than room ambient. Therefore, consideration should be
given to installing the equipment in an environment compatible with the maximum
ambient temperature (T

max

) specified;

Installation of the equipment in a rack should be such that the amount of air flow required
for safe operation of the equipement is not compromised;

Mounting of the equipment in the rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading;

Consideration should be given to the connection of the equipment to the supply circuit
and the effect that overloading of the circuits might have on overcurrent protection and
supply wiring. Appropriate consideration of equipment nameplate ratings should be used
when addressing this concern;

hot air

Front

cold air