4 connecting the studio signalling, 1 call and on-air signals – RCA LDK 5481 User Manual

Page 40

Advertising
background image

v4.0

LDK 5481 + LDK 4700 User’s Guide | Base unit

3-12

3.4

Connecting the studio signalling

Connect the studio signalling system to the rear of the base unit. The wiring of the panel
connector is shown below. Refer to the next chapter for the location of this connector.

Figure 3-4. Signalling / Intercom / Auxiliary connector

3.4.1

Call and On-air signals

There are two connection methods for the Call and On-air signalling functions:

1.

Dry contact

2.

Voltage level

The connection method for the signalling functions is set by a jumper on the main board of the
base unit. Remove the upper lid of the base unit and locate jumper X317 at the bottom centre
of the board. The settings of the jumper are shown below:

Figure 3-5. Jumper settings for signalling

4

1

2

3

5

6

7

8

9

10

11

12

13

14

15

1 2 3 4 5 6

On

Side view of switches

Off

1.

Intercom PROD Out (4-wire) or Intercom PROD In/Out
(2-wire)

2.

Call send (dry contact to pin 10)

3.

n.c.

4.

On Air send (dry contact to pin 12)

5.

Intercom PROD In

6.

Private data In

7.

Private data Out

8.

Housing

9.

Camera microphone Out return

10.

Call return

11.

n.c.

12.

On Air return

13.

Intercom PROD In return (4-wire) or not connected (2-
wire)

14.

n.c.

15.

Common ground

15-pin male D-connector; panel view

Panel part number: 2411 022 05292

A 4-wire (Off) or 2-wire (On) intercom system
is selected with rocker switch number 1.

+

C

A

12

D

19

B

26

5

+

L1500

K6000

MP7502

X312

R

6

005

C9507

C7516

IC7503

C

1500

IC

9500

C9503

R9

5

3

1

X317

R9

5

3

2

R9

5

3

3

R

953

6

R

9534

MP2004

R

5021

MP2000

R

2024

C2005

C2039

R

2019

R2023

R2022

C7513

C

A

dry contact

voltage level

D

B

C

A

D

B