Verify firmware version – RCA Fibre Channel Switch User Manual

Page 15

Advertising
background image

Configuring your Fibre Channel switch

16 April, 2003

Fibre Channel Switch

15

AdminTimeout

(dec value 0-1440 minutes, 0=never)

[30]

TempMonitoringWarning

(dec value 0-100 degrees Celsius)

[65]

TempMonitoringFailure

(dec value 0-100 degrees Celsius)

[70]

TempFailurePortShutdown

(True / False)

[False]

SecurityEnabled

(True / False)

[False]

LocalLogEnabled

(True / False)

[True]

RemoteLogEnabled

(True / False)

[False]

RemoteLogHostAddress

(dot-notated IP Address)

[10.0.0.254]

Do you want to save and activate this system setup? (y/n): [n] y

Verify firmware version

You can use the show switch command to view switch information and confirm that
the active firmware version is correct. The minimum qualified image is:

• 1.5.0.8 or higher

Contact your Grass Valley representative to determine the current required version.

To view the current version information:

1. In administrator mode type the following command at the prompt,:

sb5_8port (admin) #> show switch

2. View the switch information, an example of which is shown here. Note that the

ActiveSWImage specifies which SWImageVersion is being used. In this case, it’s
image 2.

Switch Information

------------------

SymbolicName sb5_8port

SwitchWWN 10:00:00:c0:dd:01:a6:47

SwitchType Sanbox2-8C

PROMVersion V1.4.0.2-0 (Thu Mar 13 21:27:06 2003)

CreditPool 0

DomainID 100 (0x64)

FirstPortAddress 640000

FlashSize - MBytes 128

LogLevel Critical

MaxPorts 8

NumberOfResets 17

ReasonForLastReset PowerUp

SWImageVersion (1) - build date V1.4.0.39-0 (Tue Jan 21 08:11:16 2003)

SWImageVersion (2) - build date V1.5.0.8-0 (Thu Mar 13 21:27:06 2003)

ActiveConfiguration default

ActiveSWImage 2

AdminState Online

AdminModeActive True

BeaconOnStatus False

OperationalState Online

PrincipalSwitchRole False