22

Fibre Channel Switch

16 April, 2003

Trap Severity Options

---------------------

unknown, emergency, alert, critical, error, warning, notify, info, debug, mark

Contact

(string, max=32 chars)

["On-call engineer"]

Location

(string, max=32 chars)

["Rack 3-B"]

Trap1Address

(dot-notated IP Address)

[192.168.217.5]

Trap1Port

(decimal value)

[162]

Trap1Severity

(see allowed options above)

[warning]

Trap1Enabled

(True / False)

[True]

Trap2Address

(dot-notated IP Address)

[192.168.216.48]

Trap2Port

(decimal value)

[162]

Trap2Severity

(see allowed options above)

[warning]

Trap2Enabled

(True / False)

[True]

Trap3Address

(dot-notated IP Address)

[0.0.0.0]

Trap3Port

(decimal value)

[162]

Trap3Severity

(see allowed options above)

[warning]

Trap3Enabled

(True / False)

[False]

Trap4Address

(dot-notated IP Address)

[0.0.0.0]

Trap4Port

(decimal value)

[162]

Trap4Severity

(see allowed options above)

[warning]

Trap4Enabled

(True / False)

[False]

Trap5Address

(dot-notated IP Address)

[0.0.0.0]

Trap5Port

(decimal value)

[162]

Trap5Severity

(see allowed options above)

[warning]

Trap5Enabled

(True / False)

[False]

ReadCommunity

(string, max=32 chars)

[public]

WriteCommunity

(string, max=32 chars)

[private]

TrapCommunity

(string, max=32 chars)

[public]

AuthFailureTrap

(True / False)

[False]

Do you want to save and activate this snmp setup? (y/n): [n] y

Your monitoring station should now receive all traps from your Fibre Channel switch.
You can test this by creating a fault condition, such as disconnecting one of your Fibre
Channel connections to the Fibre Channel switch. A message should appear in the
NetCentral manager.