Typical installation – Ruud PowerVent 2 AP13370-2 User Manual

Page 17

Advertising
background image

17

Typical Installation

Heat Trap
6" (15cm) Min.

Heat Trap

6" (15cm)

Min.

Flue Pipe (ABS or PVS)
to Outside Vent Terminal

Rubber Coupling

Blower Assembly

Anode

(locate d undernea th

Blower Assembly)

Union

Union

To Cold
Water Supply

Thermal Expansion

Tank

(If Required)

Shut-off Valve

Air Gap
6" (15cm)

Hot Water
Outlet t o
Fixtures

To Gas
Supply

Manual Gas
Shut-off

Sediment Trap

Cap

Drain Pan Pipe
to suitable drain

Auxiliary Catc h Pan

Thermo static
Gas Valve

Jacket Doo r

Ground Join t Union

Drain Valve

Relief valve discharge
line to suit able open
drain

Temper atu re & Pressure

Relief Valve

Pitch up 1/4"

per foot

NOTICE: The National
Fuel Gas Code (NFGC) or
CAN/CSA B149,
Installation Code,
mandates a manual gas
shut-off valve: See (NFGC)
or (CAN/CSA B149) for
complete instructions.
Local codes or plumbing
authority requirements
may vary from the
instructions or diagrams
provided and take
precedent over these
instructions.

Vacuum Relief Valve

(Not Supplied)

If required, install per local codes

and valve manufacturer’s

instructions.

Advertising