Combination potable and space heating application – Ruud PowerVent 2 AP13370-2 User Manual

Page 19

Advertising
background image

Tee fitting for vertical hot
water supply lines.

Hot water
supply to
house

From HOT

outlet on

water heater

Hot water
supply to
heating
unit

Supplemental instructions for gas water heaters installed
in potable/space heating applications.

Local codes or plumbing authority requirements may vary from the instructions or diagrams provided
in this manual and take precedent over these instructions.

Tee fitting for horizontal hot
water supply lines.

From HOT

outlet on

water heater

Hot water
supply to
house

Hot water supply
to heating unit

Combination Potable and Space Heating Application

Tee fitting must be installed as shown.
This ensures that any air in the water lines
will be purged through the domestic water
faucets and showers.

DANGER: When this system

requires water for space heating at
elevated temperatures [above 125°F
(52°C.)], a mixing or tempering valve
must be installed in the hot water
supply line to the house in order to
reduce the scald hazard potential.

DANGER: Any piping or components

used in the installation of this water
heater in a combination potable and
space heating application must be
suitable for use with drinking water.

DANGER

:

If this water heater is

installed in an application intended to
supply domestic hot water needs and
hot water for space heating purposes,
do not connect the heater to an existing
heating unit or components of a heating
system that have previously been used
with a non drinking water system. Toxic
chemicals such as those used for boiler
treatment may be present and will
contaminate the drinking water supply
causing possible health risks. Never
introduce toxic chemicals, such as those
used for boiler treatment, into this
system.

COLD

HOT

Typical Piping Diagram for Combination Potable/Space Heating Installation

Spring loaded check valve in heating

unit hot water supply line and cold

water return line (not supplied with

water heater)

NOTE: This check valve is

incorporated in some heating units.

Refer to the installation instructions

supplied with specific heating unit to

determine if it is required.

See diagrams above for proper

pipe application for vertical

or horizontal supply lines

Gas line to water heater

Cold water
return line from
heating unit

Hot water
supply line
into heating unit

Heating unit

Isolation valve in cold
water return line from
heating unit (not
supplied with water
heater)

Mixing or
tempering

valve (refer

to warning

above)

Water Heater Jacket

Temperature and pressure

relief valve discharge line

Drain valve
(not supplied with water
heater)

Temperature and Pressure

Relief Valve

Isolation valve in hot water supply line

to heating unit

(not supplied with water heater)

Incoming cold
water supply

Domestic hot water supply

Air vent

19

6” (15cm)Air Gap to Drain

Thermal Expansion
Tank (if required-not
supplied with water
heater)

Heat Trap

6” (15cm)
Min.

Shut-Off
Valve