Before you call for service – Ruud PowerVent 2 AP13370-2 User Manual

Page 25

Advertising
background image

Problem

Possible Causes

What To Do

Condensation

This usually happens when

This is normal. After the water in the tank warms

a new water heater is

up, the condensation will disappear. If, however, the

filled for the first time.

condition persists, examine the piping and fittings
for possible leaks.

Moisture from the products

This is normal and will disappear in time. Excessive

of combustion condensing

condensation can cause pilot burner outage.

on the tank surface.

An undersized water

Use a water heater size that meets the requirements

heater will cause

of your needs.

condensation.

Yellow flame

Scale on top of the burner.

Contact a qualified service technician to remove scale.

or soot

Flue or Combustion air inlet

Remove obstruction or debris from flue or

openings are restricted.

combustion air inlet openings on water heater jacket.

Not enough combustion or

Proper operation of the water heater requires air for

ventilation air supplied to

combustion and ventilation. See the Combustion and

the water heater location.

Ventilation Air information in the “Installing The
Water Heater” section of this manual.

Air Shutter Adjustment

Refer to the Adjustment Section in “Operating the Water

(LP models only)

Heater”.

Pilot burner not

Air in gas line.

Contact a qualified service technician to purge the air

lighting

from the gas line.

Pilot burner orifice clogged.

The pilot burner should be cleaned or replaced by a
qualified service technician.

Pilot burner tube pinched or

The pilot burner should be cleaned, repaired or

clogged.

replaced by a qualified service technician.

Temperature dial not

See the “Lighting The Water Heater” section of this

correctly positioned.

manual.

Rumbling noise

Scale and sediment

Clean tank.

in tank.

Relief valve

Pressure build up

This is an unacceptable condition and must be

producing popping

caused by thermal

corrected. Contact the water supplier or plumbing

noise or draining

expansion to a

contractor on how to correct this. Do not plug the

closed system.

relief valve outlet.

Water is too hot

The gas control (thermostat)

See the “Water Temperature Setting” of The Water

is set too high.

Heater section of this manual.

Gas Control (Thermostat)

Contact a qualified service technician to replace the

Defective.

gas control (thermostat).

CAUTION: For your safety DO NOT attempt repair of electrical wiring, gas piping, gas control (thermostat), burners, vent
connectors or other safety devices. Refer repairs to qualified service personnel.

CAUTION: Make certain power to water heater is “OFF” before removing protective cover FOR ANY REASON.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring error can cause improper and dangerous
operation. VERIFY PROPER OPERATION AFTER SERVICING.

Before You Call For Service…

Troubleshooting Tips

Save time and money! Review the charts on the following pages first and you may not need to call for service.