Maintenance, Fan maintenance, Glass gasket – Regency I31-NG3 User Manual

Page 19

Advertising
background image

19

Regency I31-3 Gas Fireplace Inbuilt

FAN MAINTENANCE

If your fan requires maintenance or replace-
ment, access to the fan is through the plate on
the rear wall of the firebox. NOTE: the unit
MUST NOT be operated without the fan
access panel securely in place.

CAUTION: Label all wires prior to
disconnection when servicing
controls. Wiring error can cause
improper and dangerous opera-
tion.

Remove the 2 screws holding the

grate in position.

Remove the 2 screws,

push Burner Tray to the left, and lift off.

MAINTENANCE

10) Unplug the black wires from the fan motor

(from inside the stove).

11) Lift Fan Assembly off of the 2 pins, tip

forward and pull through firebox opening.

12) Disconnect green wire from power cord.

Replacing fan:

Reverse above steps. Hint for pushing fan
down onto pins - rub a bit of dish soap on the
grommet so it will slide more easily onto the pin.
Check to make sure the fan is seated properly
on the pins, this is very important- try to move
the fan back and forth, there should be no
noise, if there is check that the grommets
haven't come loose.

To remove fan:

1) Turn the unit off and allow it to cool to room

temperature.

2) Unplug or disconnect power source to

stove.

3) Remove glass front (see page 10).

4) Remove logs.

5) Remove brick panels.

6) Remove the Grate by removing the screws

on each side of the grate.

7) Remove the Burner Tray by removing the

screws on each side of the tray. Push the
tray to the left and lift up.

8) Remove the 11 screws holding the Access

Panel in place.

9) Remove the Fan Air Duct by removing 4

screws, 2 per side.

GLASS GASKET

If the glass gasket requires replacement use
7/8" flat glass gasket (Part # 936-243) for the
Bay Front and for the Flush Front.

Advertising