Installation, Gas connection, Minimum fireplace dimensions – Regency I31-NG3 User Manual

Page 6: Minimum clearances to combustibles

Advertising
background image

6

Regency I31-3 Gas Fireplace Inbuilt

GAS CONNECTION

3) Locate the center point where the flue will

pass through the chimney above the appli-
ance. Move the appliance into the exact
location where it is to be installed. Ensure
that the Insert is level.

4) The installer must provide a valve with a

plugged tapping, accessible for test gauge
connection, immediately upstream of the
gas supply connection to the appliance.

CAUTION: If the glass is removed or
opened for servicing, it must be re-
placed and closed prior to operating the
appliance. The glass must be fixed in the
door when operating.

GAS CONNECTION WARNING:
Only persons licensed to work with
gas piping may make the neces-
sary gas connections to this appli-
ance.

1) If the appliance is to be installed into an

existing chimney system, thoroughly clean
the masonry or factory built fireplace.

2) The gas connection is 12" BSP.

SPECIFICATIONS

INSTALLATION

NOTE: Mantel clearances for Installation

into a Zero Clearance Kit are differ-
ent. Please refer to the Zero Clear-
ance Kit Manual for details.

Mantel Clearances with

Bay and Flush Louvres in

Masonry Installation

MINIMUM FIREPLACE

DIMENSIONS

The minimum fireplace dimensions for the Re-
gency gas space heater are shown in the
following diagrams:

Note: A non-combustible mantel may

be installed at a lower height if the
framing is made of metal studs
covered with a non-combustible
board.

MINIMUM

CLEARANCES TO

COMBUSTIBLES

The minimum fireplace clearances for the Re-
gency gas space heater are shown in the
following diagrams:

From Unit

Sides

A 255 mm

Ceiling

B 1205 mm

Mantle

C see Mantel

Clearances

From Surround
(660 mm x 1016 mm)

Max. Mantle Depth

G 305 mm

Hearth Height

H 0 mm

Hearth Depth

I

405 mm

Hearth Width

J 1015 mm

Min. Alcove Width

K 1220 mm

Max. Alcove Depth

L 915 mm

NG

LPG

INJECTOR

#37

#52

SIZE

2.65mm

1.6mm

INPUT

Min. 17 mj/h

Min. 17 mj/h

RATING

Max. 31 mj/h

Max. 31 mj/h

MANIFOLD

PRESSURE Max. 0.9 kPa

Max. 2.59 kPa

Advertising