Chapter 3: Installation

25

Power supply connections

SeaTalk systems

CAUTION:
When instruments are connected to SeaTalk, ensure that the
power supply for the SeaTalk 12 V line is protected by a 5 A fuse.

Systems with a large number of instruments on the SeaTalk bus may require
connections to the power supply from each end of the system (‘ring-main’ style),
to maintain sufficient voltage throughout the system.

This requirement depends on the total length of the cable run and the total
number of instruments in the system, as follows:

Cable run

No. of instruments

Power connections

Up to 10 m

13 maximum
26 maximum

1
2

Up to 20 m

7 maximum
13 maximum

1
2

D4345-2

Blue

Red

Green

Yellow

Screen

Cable from Rotavecta

Cable from Wind Vane

SeaTalk cable

SeaTalk cable

Connections to ST60 Wind instrument