Reliance Water Heaters 317775-000 User Manual

Page 23

Advertising
background image

23

cautIon

LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND

DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.

power vent wIrInG scheMatIc - fIGure 19.

may be easier to mark both the inside and outside wall. Align holes by

drilling a hole through center of the template from the inside through to

the outside. The template can now be positioned on the outside wall

using the drilled hole as a centering point for the template.

3. A) MASONRY SIDE WALLS

Chisel an opening approximately one half inch (1.3 cm) larger

than the marked circle.

B) WOODEN SIDE WALLS

Drill a pilot hole approximately one quarter inch (0.64 cm) outside

of the marked circle. This pilot hole is used as a starting point

for a saws-all or sabre saw blade. Cut around the marked circle

staying approximately one quarter inch (0.64 cm) outside of the

line. (This will allow the vent to easily slide through the opening.

The resulting gap will be covered up by the Vent Terminal cover

plate.) Repeat this step on inside wall if necessary.

SEQUENCE OF INSTALLATIONS, FIGURE 18

Cut a length of PVC pipe about 3.5 inches (8.9 cm) longer than wall

thickness at the opening. Glue vent terminal to this section of pipe. Slide

the wall plate over the pipe to stop against the vent terminal. Place a

bead of caulking (not supplied) around the gap between the pipe and

cover plate. Apply enough to fill some of the gap between the pipe

and wall. Place some of the caulking on the back of the plate to hold it

against the wall after installation. If the vent pipe is installed up to the

wall, with a coupling on the end against the wall opening, the pipe with

the vent terminal can be prepared for gluing before inserting through

the wall. Slide the pipe through the wall and insert into the coupling on

the other side of the wall, making sure that the vent terminal ends up

pointed in the correct position, see Figure 18.

vent terMInatIon - fIGure 18.

Advertising