trouBleshootInG GuIdelInes

trouBle shootInG

Please check guidelines below. For your safety, water heater service should be performed only by a qualified service technician.

Read the GENERAL SAFETY INFORMATION section first.

INTELLI-VENT TROUBLESHOOTING CHART - USER CONTROL

PROBLEM

SOLUTION

Ignition/flame failure.

6

The water heater has reached the

maximum number of retries and is

currently locked out for one hour.

Cycle the power to the water heater

off and on to reset.
Service Note:

The resistance (ohms) of a hot surface

ignitor will increase over time. If the

resistance at room temperature is near

18.8 ohms - consider replacing the ignitor

as a preventative measure.

Self diagnostic tests have found a problem 1. Turn the power off for 10-20 seconds then on again to

7

with the gas valve driver circuit, internal

clear these error codes.

microprocessor, or other internal circuits. 2. If any of these error codes persist or cannot be cleared-

replace the Intelli-Vent™ control.

8

9

Flame signal has been sensed out of

1. Turn the power off for 10-20 seconds and then on again

10

proper sequence.

to clear this error code.

2. Replace the Intelli-Vent™ control if this error code persists.

Water temperature in the tank has

1. Turn the power off for 10-20 seconds then on again

11 exceeded 195°F (91°C) and has

to clear this error code.

activated the ECO.

2. Replace the Intelli-Vent™ if the error code persists.

The self diagnostic check detected one

12

13

14

or both of the temperature adjust buttons

are stuck.

The self diagnostic test has detected the

water temperature sensor (thermistor) is

either open or shorted.

2. Replace the Intelli-Vent™ control if this error code persist.

# LED STATUS

WA

TE

RH

EA

TE

RC

ONTROL

B C D E F

B C D E F

B C D E F

B C D E F

B C D E F

B C D E F

B C D E F

B C D E F

B C D E F

1. Press and release temperature adjust buttons. If above

action does not clear error, control will continue to regulate

water temperature at last setting. However, settings will no

longer be adjustable - the control should be replaced.
1. Turn power off for 10-20 seconds then on again to

clear this error code.

4. Ensure the flame sensor is clean - use ultra fine steel

wool or Scotch-Brite™ pad to clean flame sensor.
5. Ensure the hot surface ignitor is positioned to provide

consistent ignition.
6. Check for any cracks in ignitor assembly ceramic

insulators - replace ignitor assembly if damaged.
7. Check resistance of ignitor at room temperature (77ºF)

(25°C) at the plug end. Replace ignitor if resistance is

not within 11.5 and 18.8 ohms at room temperature.
8. Ensure correct size of vent pipe (2”, 3”, 4”) was used per

installation manual for vent length. Using larger pipe than required

may cause excessive air turbulance in combustion chamber.

1. Turn off power to the water heater.

2. Insure black resistor wire is not cut, missing, and is installed

between pins 3 & 4 of ignitor assembly plug. Replace ignitor

assembly if damaged or defective.

3. Unplug ignitor assembly plug from control. Check resistance

of black resistor wire between pins 3 & 4 with an ohm meter.

3.1 If reading taken is less than 2000 (5000 for date code 0617

through 0709) or more than 1.7 million ohms, replace ignitor

assembly. 3.2 If reading taken is between 2000 (5000 for date

code 0617 through 0709) and 1.7 million ohms, replace

Intelli- Vent™ control.

Service Note: Raised ridges on ignitor assembly plug identify

#1, #2, and #3 pins. The four-digit date code can be found on

side of the controller.

Self-diagnostic test found a problem with black

resistor wire on the ignitor assembly plug; resistor

wire is open or shorted.
Service Note: To perform this test ohm meter

used must be capable of reading up to 2,000,000

ohms. Unless ohm meter used has an auto-range

feature resistance should be checked twice. First

reading will be taken using an ohms scale above

1,700,000 ohms. Second reading is taken using

ohms scale just above 2,000 or 5,000 ohms.

2. Low supply voltage - should be 115 -125 VAC.
3. Ensure flame sensor is making good contact with burner

flame, ensure flame is steady see #8 below.

1. Gas supply is turned off-pressure too low. Ensure supply and

manifold gas pressures are within requirements in installation

manual. Manifold gas pressure is non-adjustable if pressure is

off by more than 0.3” W.C. (75 Pa) replace Intelli-Vent™ control.