The anode rod is used to protect the tank from corrosion. Most hot water

tanks are equipped with an anode rod. The submerged rod sacrifices

itself to protect the tank. Instead of corroding tank, water ions attack

and eat away the anode rod. This does not affect water’s taste or color.

The rod must be maintained to keep tank in operating condition.
Anode deterioration depends on water conductivity, not necessarily

water condition. A corroded or pitted anode rod indicates high water

conductivity and should be checked and/or replaced more often than

an anode rod that appears to be intact. Replacement of a depleted

anode rod can extend the life of your water heater. Inspection should

be conducted by a qualified technician, and at a minimum should be

checked annually after the warranty period.

teMperature-pressure relIef valve test

DANGER

Burn hazard.

Hot water discharge.

Keep clear of Temperature-

Pressure Relief Valve

discharge outlet.

It is recommended that the Temperature-Pressure Relief Valve should be

checked to ensure that it is in operating condition every 6 months.
When checking the Temperature-Pressure Relief Valve operation, make

sure that (1) no one is in front of or around the outlet of the Temperature-

Pressure Relief Valve discharge line, and (2) that water discharge will

not cause any property damage, as water may be extremely hot. Use

care when operating valve as the valve may be hot.
To check the relief valve, lift lever at the end of valve several times,

see Figure 28. The valve should seat properly and operate freely.
If after manually operating the valve, it fails to completely reset and

continues to release water, immediately close the cold water inlet to

the water heater and drain the water heater, see Draining And Flushing

on page 31. Replace the Temperature-Pressure Relief Valve with a

properly rated/sized new one, see Temperature-Pressure Relief Valve

on page 15 for instructions on replacement.

DISCHARGE PIPE

TEMPERATURE-PRESSURE

RELIEF VALVE

Figure 28.

If the Temperature-Pressure Relief Valve on the water heater weeps

or discharges periodically, this may be due to thermal expansion.
Note: Excessive water pressure is the most common cause of

Temperature-Pressure Relief Valve leakage. Excessive water system

pressure is most often caused by “thermal expansion” in a “closed

system.” See Closed Water Systems and Thermal Expansion on

page 29. The Temperature-Pressure Relief Valve is not intended for

the constant relief of thermal expansion.
Temperature-Pressure Relief Valve leakage due to pressure build

up in a closed system that does not have a thermal expansion tank

installed is not covered under the limited warranty. Thermal expansion

tanks must be installed on all closed water systems.
do not pluG the teMperature-pressure relIef valve

openInG. thIs can cause propertY daMaGe, serIous

InjurY or death.

Explosion Hazard

Temperature-Pressure Relief Valve

must comply with ANSI Z21.22-

CSA 4.4 and ASME code.

Properly sized Temperature-Pressure

Relief Valve must be installed in

opening provided.
Can result in overheating and

excessive tank pressure.
Can cause serious injury or death.

draInInG and flushInG

It is recommended that the water heater storage tank be drained and

flushed every 6 months to reduce sediment buildup. The water heater

should be drained if being shut down during freezing temperatures.

See Typical Installation section in this manual for location of the water

heater components described below.

DANGER

Burn hazard.

Hot water discharge.

Keep hands clear of drain

valve discharge.

to draIn the water heater storaGe tanK:

1. Turn off the electrical supply to the water heater.

2. Turn off the gas supply at the Main Gas Shutoff Valve if the water

heater is going to be shut down for an extended period.

3. Ensure the cold water inlet valve is open.

4. Open a nearby hot water faucet and let the water run until the

water is no longer hot.

5. Close the cold water inlet valve to the water heater.

6. Connect a hose to the water heater drain valve and terminate it

to an adequate drain.

7. Open the water heater drain valve and allow all the water to drain

from the storage tank.

8. Close the water heater drain valve when all water in the storage

tank has drained.

9. Close the hot water faucet opened in Step 4.

10. If the water heater is going to be shut down for an extended period,

the drain valve should be left open.

to flush the water heater storaGe tanK:

11. Turn off the electrical supply to the water heater.

12. Ensure the cold water inlet valve is open.

13. Open a nearby hot water faucet and let the water run until the

water is no longer hot. Then close the hot water faucet.

14. Connect a hose to drain valve and terminate it to an adequate drain.

15. Ensure the drain hose is secured before and during the entire

flushing procedure. Flushing is performed with system water

pressure applied to the water heater.

16. Open the water heater drain valve to flush the storage tank.

17. Flush the water heater storage tank to remove sediment and allow

the water to flow until it runs clean.

18. Close the water heater drain valve when flushing is completed.

19. Remove the drain hose.

20. Fill the water heater - see Filling The Water Heater in this manual.

21. Turn on electrical supply to place water heater back in operation.

22. Allow the water heater to complete several heating cycles to ensure

it is operating properly.