Raypak RFSDV34RFPAU User Manual

Page 16

Advertising
background image

remote control within 30 seconds. The LED will blink indicating the
remote control will now work with the receiver valve. If the switch
continues in the REMOTE position, the remote control will now control
the main valve, flame modulation level and fan control.

7. If the manual switch is in the LOCAL position, the valve will be at the

highest fixed pressure setting and the fan will be at the highest fixed
speed. The remote control will control the fan speed only.

Fig. 6 Comfort Control Valve

Shut Off Procedure

If the manual switch is in the REMOTE position, the remote control can
shut off the main burner and fan. However, if the control is still ON a
command from the remote control can turn on the main burner or fan.

To shut off the system, turn the pilotstat knob clockwise to the OFF
position. This action closes the main gas and safety valves. The remote
control cannot turn on the main burner or fan.

Remote Control Operation

Refer to Fig 7

OFF Mode

In the OFF mode, the fireplace flame and fan are off, the display will show
OFF and display the room temperature. If the receiver is in the REMOTE
mode, the fireplace will shut off.

ON Mode (Manual)

In the ON mode, the room temperature, flame and fan levels will be
shown. MANUAL will appear next to both the flame and fan icons.

When the control is in the ON mode, you can change the flame and fan
levels and the delay timer with the Up and Down buttons. To change the
flame level, press the Flame button followed by an arrow key. To change
the fan level, press the Fan key followed by an arrow key. Pushing the
arrow key once changes the level by one unit

Page 16 of 27

Advertising
This manual is related to the following products: